☠️ WARNING ☠️ Turn OFF and UNPLUG the machine before starting.

New Solenoid diagram
New Solenoid diagram
  1. Open the lower right side panel with the cabinet key, and locate the stock solenoid.
    Side panel, solenoid
    Side panel, solenoid
  2. Remove the upper and lower air lines from stock solenoid. Press the blue plastic retainer towards the brass fitting and pull on the line with the other hand.
    stock solenoid
    Stock solenoid
  3. Unscrew the black plastic thumb nut holding the electrical portion of the solenoid in place.
    Thumb nut
    Thumb nut
  4. Remove the black electrical portion of the solenoid from the silver valve body.
    black electrical portion, silver valve body
    Black electrical portion, silver valve body
  5. Install the electrical portion from the old solenoid onto the new solenoid valve body. Turn the electrical portion until the wires are positioned over the "A" fitting on the valve body, and you feel it "click" into place.
    electrical portion from the old solenoid, new solenoid valve body
    Electrical portion from the old solenoid, new solenoid valve body
  6. Screw the black thumb nut into place, securing the electrical portion to the new valve body.
    Black thumb nut
    Black thumb nut
  7. Using the 6-mm couplers, connect the:
    • Air line leading up to the laser head to the air line connected to the "A" fitting on the new solenoid.
    • Air line coming from the stock air pump to the air line connected to the upper right "R" fitting.
    • Air line coming from external fitting to the air line coming from the lower right "P" fitting.
    Side panel, new solenoid
    Side panel, new solenoid
  8. Carefully lay the solenoid on the cabinet floor. Replace the side panel and lock the cabinet.