Looking for help?
Find answers to your questions
- LightBurn Setup Using Free Trial - Before Your Machine Arrives (Mac)
- LightBurn Setup Using Free Trial - Before Your Machine Arrives (PC)
- LightBurn Setup Using LightBurn License - Before Your Machine Arrives (Mac)
- LightBurn Setup Using LightBurn License - Before Your Machine Arrives (PC)
- LightBurn Setup Using LightBurn License - After Your Machine Arrives (Mac)
- LightBurn Setup Using LightBurn License - After Your Machine Arrives (PC)
- LightBurn Setup For A Galvo Fiber Laser (Mac)
- LightBurn Setup For A Galvo Fiber Laser (PC)
- LightBurn Basics
- Squaring the Laser Head MIRA
- Manual Focus MIRA
- Move Y-Sensor Bracket
- Bed Will Not Raise
- Aligning Mirrors MIRA
- Why Is My CO2 Laser Not Cutting?
- 5 Point Test - MIRA
- 5 Point Test - NOVA
- How to Manage an Auto Focus Crash - MIRA
- Step Per Rotation - Roller Rotary
- Common Machine Errors and Solutions
- Step Length Test - Multi-Roller
- Connectivity Issues - Fiber Lasers
Solenoid Retrofit MIRA 7
☠️ WARNING ☠️ Turn OFF and UNPLUG the machine before starting.
- Open the lower right side panel with the cabinet key, and locate the stock solenoid.
- Remove the upper and lower air lines from stock solenoid. Press the blue plastic retainer towards the brass fitting and pull on the line with the other hand.
- Unscrew the black plastic thumb nut holding the electrical portion of the solenoid in place.
- Remove the black electrical portion of the solenoid from the silver valve body.
- Install the electrical portion from the old solenoid onto the new solenoid valve body. Turn the electrical portion until the wires are positioned over the "A" fitting on the valve body, and you feel it "click" into place.
- Screw the black thumb nut into place, securing the electrical portion to the new valve body.
- Using the 6-mm couplers, connect the:
- Air line leading up to the laser head to the air line connected to the "A" fitting on the new solenoid.
- Air line coming from the stock air pump to the air line connected to the upper right "R" fitting.
- Air line coming from external fitting to the air line coming from the lower right "P" fitting.
- Carefully lay the solenoid on the cabinet floor. Replace the side panel and lock the cabinet.